Boiler Retra Univer P 40 kW

Article: 000003556

58000грн

In Stock

Manufacturer: Ретра Chimney pipe diameter, mm: 200 Flue gas temperature, °C, not exceeding: 140-160 Nominal fuel consumption, kg/h, not more than: pellets (Q=18000 kJ/kg) 9.3 anthracite (Q=27200 kJ/kg) 6.2 Supply voltage, V/frequency, Hz: ~220/50 Chimney outlet, mm: 200 Thickness of the internal wall of the heat exchanger, mm: 5 Vacuum behind the boiler, Pa, not less than: 25 Water jacket volume, liters: 150 Water temperature at the boiler inlet, not less than, ºC: 55 Water temperature at the boiler outlet, not exceeding, ºC: 90 Condition: New Brand: Retra Type of fuel: Solid lump (firewood, brown coal and hard anthracite, briquettes from wood processing waste, husks) Furnace volume, L: 157 Height of the chimney from the axis of the boiler flue, m: 7

Warranty:specify
Why Kotel-Prom?
  • All products are certified

  • Quality first

  • Return within 14 days

  • Warranty on all products

Delivery options:
  • Self-pickup(map)

  • Courier delivery in Kharkiv

  • Delivery across Ukraine

Payment methods
  • Cash on delivery

  • Non-cash payment

  • Bank transfer to card

  • Bank transfer to current account

Boiler Retra Univer P 40 kW

Fuel

Solid lump (firewood; brown and hard coal; anthracite; briquettes from wood processing waste, sunflower husks, straw, peat), chips, sawdust, pellets.

Application

It is used for central heating of individual homes and residential complexes, administrative, industrial and warehouse premises, especially wood processing plants, livestock complexes, pavilions, greenhouses, schools, shops, and medical institutions.

Advantages of Retra-Univer R boilers

  • Efficiency up to 86-93% due to design features;
  • versatility: the boiler operates on any type of solid fuel;
  • microprocessor control of the boiler and heating system;
  • the possibility of refilling fuel while the boiler is operating;
  • Turbulators increase boiler efficiency and simplify cleaning;
  • the boiler is equipped with a lined chamber for afterburning pyrolysis gases;
  • The boilers are equipped with a mechanical fuel loosener.

General characteristics

The Retra-Univer R boiler is constructed of durable sheet metal with a highly developed heat-receiving surface. The Retra-Univer R boilers are domestic boilers that burn wood gas, which is released during smoldering. Fuel is loaded manually, and a flare burner can be installed. Ash removal from the grate is manual. The boilers are equipped with a mechanical fuel aerator.

Technical characteristics of the Retra-Univer P boilers 25-98 kW

1. loading hatch;
2. stud hatch, also used for installation of a flare burner;
3. ash tray;
4. side hatch for cleaning the flue;
5. Upper hatch for cleaning the flue;
6. feed pipe;
7. return pipe;
8. chimney;
9. chimney damper;
10. Upper ash pit hatch;
10a. Lower ash pit hatch;
11. smoke exhauster;
12. control panel;
13. pressure gauge;
14. tap for filling (draining) water;
15. copper sleeve for installing a temperature sensor;
16. water jacket;
17. combustion chamber (firebox);
18. lined wood gas afterburning chamber;
19. turbulators;
20. partition with pipe filling;
21. removable grate;
22. grate cleaning mechanism;
23. turbulator drive mechanism;
24. heat-insulating casing;
25. direct draft damper;
26. straight partition.

Control system for solid fuel boiler RETRA- Univer P

The boiler design allows for its operation together with an electronic control panel, blower fans, and a smoke exhauster.

The control panel is designed to operate a central heating boiler, which is equipped with a smoke exhauster and a water circulation pump for the heating system. It automatically maintains the set boiler temperature using a smoke exhauster.

Before starting to operate the boiler, the user must read the documentation for the control panel.

The control panel can be installed directly on the boiler in areas protected from high temperatures and direct flame exposure, as well as on adjacent walls of the boiler room, provided that there is unimpeded and safe access to the control panel.

The temperature of the coolant (water) is measured using a temperature sensor installed in a copper sleeve (15) mounted on top of the boiler's heat exchanger near the supply pipe. An emergency temperature sensor is also connected to the copper sleeve. If the boiler temperature exceeds 95 ° C, it opens the contacts and shuts down the smoke exhaust fan (the circulation pump continues to operate).

When using the boiler in the automatic fuel supply mode, use only the control panel supplied with the flare burner.

The operating principle of the fuel combustion device (torch burner) and its control panel are described in the passport for these devices.

Overall and connection dimensions of boilers of the "Retra-Univer P" model series with a capacity of 25-98 kW

Passport for the Retra Univer R boiler

Technical characteristics of boilers of the "Retra-Univer P" model range with a capacity of 25-98 kW

Do you have any questions? Need a consultation?
+38 (066) 364-20-64

Order a call back

Reviews (0):
    Similar Products: