Boiler Retra-5M Komfort 15 kW

Similar Products:
Article: 000003564

26500грн

In Stock

Manufacturer: Ретра Chimney pipe diameter, mm: 180 Flue gas temperature, °C, not exceeding: 140 Nominal fuel consumption, kg/h, not more than: pellets (Q=18000 kJ/kg) 2.58-2.7, anthracite (Q=27200 kJ/kg) 1.2-2.3, firewood (Q=12000 kJ/kg) 2.8-5.2 Supply voltage, V/frequency, Hz: 220/50 Chimney outlet, mm: 140x160 Thickness of the internal wall of the heat exchanger, mm: 4 Vacuum behind the boiler, Pa, not less than: 25 Water jacket volume, liters: 70 Water temperature at the boiler inlet, not less than, ºC: 55 Water temperature at the boiler outlet, not exceeding, ºC: 95 Condition: New Brand: Retra Type of fuel: primary: pellets; backup: firewood, coal, briquettes Furnace volume, L: 55 Height of the chimney from the axis of the boiler flue, m: 6

Warranty:specify
Why Kotel-Prom?
  • All products are certified

  • Quality first

  • Return within 14 days

  • Warranty on all products

Delivery options:
  • Self-pickup(map)

  • Courier delivery in Kharkiv

  • Delivery across Ukraine

Payment methods
  • Cash on delivery

  • Non-cash payment

  • Bank transfer to card

  • Bank transfer to current account

Boiler Retra-5M Komfort 15 kW

The pellet burner and hopper are not included in the kit and must be purchased separately.

The RETRA-5M KOMFORT solid fuel boilers are domestic boilers that can be equipped with a pellet burner (torch type) and a fuel supply system with a hopper. The boiler operation is controlled by a microprocessor, with automatic fuel supply (primary mode). The RETRA-5M KOMFORT boilers also feature a turbocharger and a control panel for manual fuel loading (standby mode).

The boilers are designed for operation in central water heating systems with forced (closed pressure heating system) or natural (open heating system) circulation of the coolant for heating and hot water supply of residential buildings, summer cottages, industrial and warehouse premises, retail facilities, social and administrative buildings.

Optionally, the Retra-5M KOMFORT boilers are adapted to operate in two modes:

  1. Automatic fuel supply (pellets from various types of wood).
  2. Manual fuel supply (wood, coal, briquettes, etc. large-fraction fuel).

Advantages of the Retra-5M KOMFORT boiler series:

  • The boiler design allows burning different types of fuel (wood, coal, briquettes, wood waste).
  • The arrangement of horizontal (convector) chambers provides a minimal effect of flue gas condensation, which significantly extends the service life of the boiler.
  • The manufacturer has adapted the boiler to operate in automatic mode with a pellet burner and a fuel supply system with a hopper (main mode), as well as an electronic control system and air supply with manual fuel loading (backup mode).
  • Warranty - 3 years!

Boiler device

The steel heat exchanger (1) consists of two parts: the lower part houses the combustion chamber (2), while the upper part contains straight baffles (3), which form the heat exchanger's convection channels. The straight baffles and the heat exchanger walls are water-cooled, forming the so-called "water jacket." Combustion occurs in the combustion chamber using a flare burner (27) in automatic mode or on water-cooled grate bars (22) in manual mode. An ash pan (11) is located in the grate bar. Flue gases, after passing through the heat exchanger's convection channels, enter the chimney (4).


  1. steel heat exchanger;
  2. combustion chamber (firebox)
  3. the partition is straight;
  4. chimney;
  5. rotary flue damper;
  6. primary air diffuser;
  7. branch pipe for draft regulator;
  8. secondary air supply channel with damper;
  9. secondary air injectors;
  10. fuel loosening agent;
  11. ash chamber (ash pan)
  12. decorative casing;
  13. loading hatch;
  14. cesspool and ash removal hatch;
  15. ash pit hatch;
  16. feed pipe;
  17. smoke duct cleaning hatch;
  18. turnover pipe;
  19. safety valve;
  20. drain pipe with ball valve;
  21. thermal insulation layer;
  22. grate;
  23. inclined heat exchanger pipes;
  24. thermo manometer;
  25. control panel;
  26. pipe for the control panel temperature sensor;
  27. pellet burner;
  28. fan.

HOW THE BOILER WORKS

Water from the heating system enters the boiler through the return pipe, spreads throughout the internal cavities of the heat exchanger, and, along its metal walls, absorbs heat from the burning fuel (via contact and radiation in the furnace) and the combustion gases (via convection in the remaining parts of the heat exchanger). Heated water enters the heating system through supply pipe 16.

Lighting a cold boiler should only begin after ensuring the boiler is sealed and truly filled with water. Open the ashpit door slightly. Lighting should be carried out with dry wood for 0.5 hours, gradually increasing the boiler outlet water temperature to 70°C. For the first time, the boiler should be heated in manual (standby) mode without a supply ventilation system (without a fan), regulating the air flow by opening the ashpit door and remembering to turn on the central heating pump when the boiler outlet temperature exceeds 40°C (subsequently, when using the fan, the pump, which is connected to the controller, will turn on automatically).

The Retra-5M KOMFORT boilers with a pellet burner and automatic fuel feed have a built-in auto-ignition function (detailed information on igniting a boiler with a pellet burner and setting up the boiler operation is described in the pellet burner data sheet).

For the first 2-3 days, it is recommended to run the boiler continuously at an outlet water temperature of 70-80°C (to eliminate condensate). Subsequently, you can program the boiler operation on the electronic controller according to the instructions provided in the controller (electronic control panel) manual.

After ignition in the boilers of the “Retra-5M KOMFORT” model, the combustion process and fuel supply are controlled automatically using an electronic control unit (controller).

The primary and secondary air distribution system in the Retra-5M KOMFORT boilers allows the boiler to operate after all doors and hatches are tightly closed, according to the operating parameters set on the controller. The only responsibility of the maintenance personnel is to promptly refill the combustion chamber (in manual mode) and the hopper (in automatic mode) with fuel.

Using a pellet burner in boilers of the Retra-5M KOMFORT model series

To install a pellet burner on the Retra-5M KOMFORT boiler, remove the bottom hatch plugs and install the pellet burner in their place. Follow the instructions provided with the pellet burner.


Characteristics of the EKO-PALNIK VIP pellet torch burner

  • The burner burns wood pellets of any quality, including agro-pellets and straw pellets;
  • The burner is easy to clean thanks to its convenient design;
  • The burner is made of stainless steel, high quality heat-resistant and acid-resistant materials;
  • The following processes are fully automated: ignition, combustion and extinguishing;
  • Burner modulation allows for efficient use of pellets;
  • Compact design and dimensions ensure easy installation in most solid fuel boilers;
  • High efficiency - 94% efficiency;
  • Low power consumption - about 20 W in operating mode;
  • Environmentally friendly, low emission level - at the level of gas and liquid fuel burners;
  • Works with a room thermostat that controls the hot water heating time and room temperature;
  • Automatic switching on and off of the burner in case of power failure;
  • High level of safety: a reliable valve that prevents backfires; a temperature sensor prevents the boiler from overheating in the event of a power outage.

Warranty: 2 years

Complete set of boilers "Retra-5M KOMFORT"

Item No.

Name

Units

Quantity

1

Pellet burner with fuel supply system (flexible auger) ***

pcs.

1

2

Bunker capacity 0.6 cubic meters ***

pcs.

1

3

Remote control

pcs.

1

4

Fan with damper

pcs.

1

5

Thermomanometer (axial)

pcs.

1

6

Safety valve 1/2" mm

pcs.

1

7

Ball valve 1/2" mm

pcs.

1

8

Plug 3/4 "p

pcs.

1

9

Sleeve for temperature sensor

pcs

1

10

Operation and installation manual for boilers of the Retra-5M type KTR-5M.01.00.000 KE

pcs.

1

11

Passport and installation and operating instructions for the pellet burner ***

pcs.

1

* - operating documents for component parts in accordance with the terms of delivery of supplier plants.
** - packaging (at customer’s request).
*** - may not be included in the delivery package upon separate order.


Overall dimensions

Retra-5M boiler data sheet

ST-24 remote control passport

Technical characteristics of boilers of the "Retra-5M" model series with a capacity of 10-32 kW

Do you have any questions? Need a consultation?
+38 (066) 364-20-64

Order a call back

Reviews (0):
    Similar Products: