In Stock

Recirculation Pump Control: No Underfloor Heating Pump Control: No Solar collector pump control: No Condition: New Three-way valve control: No Pellet burner control: No Throttle valve control: No Set temperature range, °C: 35...90 Flue gas temperature sensor: No Maximum temperature measurement range, up to °C: 100 Lambda sensor: No Mains voltage: 220~240 V Fuel level display function: Yes Component type: Automation Possibility of connecting a room thermostat-prog: Yes Fan control: Yes Automation for: Manually loaded boiler Control by the second fan: No Purpose of the component: For solid fuel boilers Control of the heating pump or the DHW pump: No Heating pump control: Yes DHW pump control: Yes

Warranty:specify
Why Kotel-Prom?
  • All products are certified

  • Quality first

  • Return within 14 days

  • Warranty on all products

Delivery options:
  • Self-pickup(map)

  • Courier delivery in Kharkiv

  • Delivery across Ukraine

Payment methods
  • Cash on delivery

  • Non-cash payment

  • Bank transfer to card

  • Bank transfer to current account

Automation for solid fuel boilers Prond Krypton PS CWU

Adjusting the operation of the blower fan and circulation pump is a task easily handled by the Prond Krypton PS CWU automation system. The control unit is designed specifically for solid fuel boilers to improve heating equipment performance and reduce maintenance costs. For maximum system customization, a room thermostat can also be used. The automation system is connected to the turbine and pump via IEC connectors. A temperature sensor, 3.15 A fuse, and power cable are other components of the housing.

Features of operation

Before starting the system, the user must set the optimal temperature parameters, which will then be automatically maintained by the controller. Fan speed control depends on
Keywords: Automatic control for solid fuel boilers Prond Krypton PS CWU, Heating, Accessories for heating equipment, Automatic control for heating equipment, accessories for heating equipment
Condition: New
Mains voltage: 220~240 V
Purpose of the component: For solid fuel boilers
Component type: Automatic
Possibility of connecting a room thermostat-program: Yes
Power consumption (W): 2
DHW pump control: Yes
Automatic control for: Manually loaded boilers
Fan control: Yes
Underfloor heating pump control: No
Fuel feed mechanism control (auger): No
Solar Collector Pump Control: No
Three-way valve control: No
Throttle Control: No
Second fan control: No
Recirculation pump control: No
Pellet burner control: No
Heating pump control: Yes
Flue gas temperature sensor: No
Lambda probe: No
Set temperature setting range, °C: 35...90
Heating pump or DHW pump control: No
Maximum temperature measurement range, up to °C: 100
Heating pump load, up to (A): 1
Anti-stop function: Yes
Anti-freeze function: Yes
Fan load, up to (A): 1
Fuel level display function: Yes
Load on the DHW pump, up to (A): 1