Moeller B40/3 circuit breaker
Moeller PL6-B40/3+N circuit breaker
Applications of Moeller circuit breakers:
Moeller circuit breakers are used in electrical circuits with a power rating of 220 and 400 V/50 Hz AC and up to 48 V/50 Hz DC to automatically shut off power in the event of a network overload, short circuit, or brownout. Moeller circuit breakers or Moeller switches pass current during normal operation and allow manual power shutoff and reconnection. Moeller circuit breakers automatically interrupt the electrical circuit, thereby preserving the integrity of household appliances and large appliances. Damage to the wiring itself is also eliminated. Buy Moeller circuit breakers in Kharkiv at the 220 Volt online store.
Moeller X-Pole PL6 series circuit breakers are widely used in household wiring for apartments, houses, and cottages. Moeller circuit breakers are installed in administrative buildings, offices, and industrial facilities to protect 220V or 400V electrical systems. Prices for circuit breakers in Kharkiv are listed in the price lists and in the Moeller circuit breaker model description.
Structure of Moeller switches:
The Moeller modular circuit breaker mounts on a standard 35mm DIN rail and offers two types of protection: thermal and dynamic. Thermal protection is based on a bimetallic strip that heats up and trips during prolonged overloads in the electrical network. Dynamic protection is characterized by the rapid response of the electromagnetic coil during short circuits. Moeller circuit breakers have a built-in arc suppressor, which helps contain the arc. Moeller circuit breakers feature robust clamps made of anodized copper and silver-plated steel for securing conductors with diameters from 1 to 25 mm2.
Features of Moeller X-Pole PL6 switches:
- Moeller circuit breakers have a high limitation of the passing electrical energy
- The clamps consist of bolts and clamps, which allows for more secure fixation of the conductors.
- Any side of the packet can be both an input and an output.
- The contacts are spaced 4mm apart to ensure safe disconnection.
- Suitable for DC power up to 48V/50Hz
- Moeller switches allow you to connect additional modules
- A connecting bus can be used
Types of protective characteristics of Moeller xpole circuit breakers:
The protective characteristic type denotes the magnitude of the alternating or direct current that causes instantaneous tripping of the electromagnetic tripping device. The value can be specified as a specific value or in units of thermal tripping current (Inp). Protective characteristic values for Moeller PL6 series circuit breakers:
- Type B – from 3 to 5 Inp (used for electrical circuits with low inrush current, such as lighting and power supply networks)
- Type C – from 5 to 10 Inp (average level of starting currents)
- Type D, K – from 10 to 14 Inp (high level of inrush currents)
- Type L – from 3 to 4 Inp
- Type U – 6 to 9 Inp
- Type Z – 2.5 to 3.5 Inp
Additional accessories for Moeller PL-6 machines:
- Auxiliary contacts Z-AHK
- Signal and auxiliary ZP-NHK
- Independent trip unit ZP-ASA
- Undervoltage release Z-USA, Z-USD
- Motor drive Z-FW-LP
- Remote control module Z-FW-MO
- Connecting systems
Technical characteristics of Moeller PL6 series machines:
- Breaking capacity – 6 kA
- Nominal voltage: 230/400 V AC, 48 V DC
- Current strength – 50 Hz
- The maximum cross-section of the connected wire is 25 sq. mm.
- Operating conditions: UHL4
- Protection class – IP20
- The weight of one module is 100 g.
- Complies with: GOST R 50345-99
Technical characteristics of the Moeller PL6-B40/3+N circuit breaker:
- Number of poles – 3+N
- Nominal current – 40 A
- Type of protective characteristic – B